Product Features
Relay coil rated at 24.0 vdc, 16.0 ohms
Product Technical Spec.
Body Style:
Multipole-multiple actuator type
Body Length:
7.120 inches
Center To Center Distance Between Terminals Parallel To Length:
5.940 inches
Center To Center Distance Between Terminals Parallel To Width:
1.500 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
3.828 inches
Switch Contact Arrangement:
Single pole, double throw
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width:
1.500 inches
Fragility Factor:
Moderately rugged
Boss Height:
0.220 inches
Mounting Surface To Terminal End Distance:
4.300 inches
Arc Quenching Method:
Deion
Mounting Facility Type And Quantity:
8 threaded hole
Storage Type:
General purpose warehouse
Thready Qty Per Inch (tpi):
32
Maximum Continuous Load Current Rating Per Pole:
130.0 amperes dc fourth location
Maximum Continuous Load Current Rating Per Pole:
45.0 amperes ac third location
Maximum Continuous Load Current Rating Per Pole:
45.0 amperes ac first location
Maximum Continuous Load Current Rating Per Pole:
45.0 amperes ac second location
Operating Voltage Type And Rating Per Pole In Volts:
130.0 dc fourth location
Operating Voltage Type And Rating Per Pole In Volts:
240.0 ac second location
Operating Voltage Type And Rating Per Pole In Volts:
240.0 ac first location
Operating Voltage Type And Rating Per Pole In Volts:
240.0 ac third location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps:
10000.0 dc fourth location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps:
18000.0 ac first location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps:
18000.0 ac second location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps:
18000.0 ac third location
Circuit Protection Type:
Overcurrent all locations
Trip Release Method:
Magnetic all locations
Trip Release Characteristic:
Time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent:
150.0 all locations
Main Contact Tripping Mechanism Type:
Trip free
Manual Actuator Type And Quantity:
4 toggle
Actuator Function:
Trip-reset
Actuator Position Designation:
At each pole
External Actuator Linkage Arrangement:
One, two, three, and four linked
Auxiliary Switch Function And Quantity:
2 control
Internal Trip Release Configuration:
Series trip first location
Internal Trip Release Configuration:
Relay trip fourth location
Internal Trip Release Configuration:
Series trip second location
Internal Trip Release Configuration:
Series trip third location
Thread Size:
0.190 inches
Switch Location And Position Designation:
Internal at each pole
Trip Delay Time In Seconds Per Rated Continuous Current:
0.250 at 200 pct and 1.000 at 200 pct first location
Trip Delay Time In Seconds Per Rated Continuous Current:
0.250 at 200 pct and 1.000 at 200 pct second location
Trip Delay Time In Seconds Per Rated Continuous Current:
0.250 at 200 pct and 1.000 at 200 pct third location
Trip Delay Time In Seconds Per Rated Continuous Current:
0.900 at 200 pct and 1.300 at 200 pct fourth location
Inclosure Protection Type For Which Designed:
General purpose
Switch Terminal Type:
Tab, solder lug
Switch Current Rating And Type In Amps:
10.0 ac and 10.0 dc
Switch Voltage Rating And Type In Volts:
250.0 ac and 30.0 dc
Frequency In Hertz:
400.0 first location
Frequency In Hertz:
400.0 second location
Frequency In Hertz:
400.0 third location
Thread Series Designator:
Unc
Terminal Type And Quantity:
8 threaded stud
Item Name:
Magnetic Circuit Protector
Cross Referenced Parts
Part Number
Cage
RNCC
RNVC
RNAAC
Status
MSDS
SADC
Part Number:
68394009-001